You have reached the quote request page for part number UPL2-27930-1 of Ai Tek Instruments Llc, we have in stock that is listed alongside the description Circuit Breaker. If you would like to learn more about this NSN part and your purchasing options, please fill out and submit the Request the Quote (RFQ) page presented on this page. By offering us important details like your target price and expected fulfillment time frame, our team can best offer you a tailored solution for your consideration. As we have staff available at all times, responses to any submission will be offered within 15 minutes of our review.
Note : We Will Not Share Your Information With Any Third Parties.
To make exploring our expansive inventory simple, we have chosen to list all offerings alongside as much information as we can for an ease of identification. For example, part number UPL2-27930-1 is specifically produced under CAGE Code 1XP56, denoting the specific Ai Tek Instruments Llc facility it traces back to. Furthermore, with the NSN 5925-01-425-1840, this item also belongs to FSC 5925 Circuit Breakers, further ensuring that you only purchase your exact needs. If you have any questions or concerns regarding our offerings or service, be sure to call or email us at your convenience. Otherwise, we look forward to serving you as your strategic sourcing partner for part number UPL2-27930-1 and more.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-425-1840 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014251840 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
UPL2-27930-1 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CPRX | Actuator Position Designation | AT EACH POLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP W/DUAL RATING ALL LOCATIONS |
FEAT | Special Features | HANDLE COLOR IS BLACK. |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 65.0 DC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 DC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.100 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.700 MAXIMUM AT 200 PCT ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
CPRW | Actuator Function | TRIP-RESET |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote