You have reached the quote request page for part number WKJ0-6D115VDC of Allied Controls Inc, we have in stock that is listed alongside the description Relay Electromagnetic. If you would like to learn more about this NSN part and your purchasing options, please fill out and submit the Request the Quote (RFQ) page presented on this page. By offering us important details like your target price and expected fulfillment time frame, our team can best offer you a tailored solution for your consideration. As we have staff available at all times, responses to any submission will be offered within 15 minutes of our review.
Note : We Will Not Share Your Information With Any Third Parties.
To make exploring our expansive inventory simple, we have chosen to list all offerings alongside as much information as we can for an ease of identification. For example, part number WKJ0-6D115VDC is specifically produced under CAGE Code 02288, denoting the specific Allied Controls Inc facility it traces back to. Furthermore, with the NSN 5945-00-008-0553, this item also belongs to FSC 5945 Relays and Solenoids, further ensuring that you only purchase your exact needs. If you have any questions or concerns regarding our offerings or service, be sure to call or email us at your convenience. Otherwise, we look forward to serving you as your strategic sourcing partner for part number WKJ0-6D115VDC and more.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-008-0553 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 000080553 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
32213WKJ060 | 2 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.320 INCHES MINIMUM AND 1.330 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.073 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.083 INCHES MAXIMUM FIRST MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 0.890 INCHES MINIMUM AND 0.900 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.390 INCHES MINIMUM AND 0.400 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.115 INCHES MINIMUM FIRST MOUNTING FACILITY AND 0.125 INCHES MAXIMUM FIRST MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 8.0 KILOHMS MINIMUM SINGLE WINDING AND 12.0 KILOHMS MAXIMUM SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SECOND MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE FIRST MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 0.468 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE FIRST MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 6.3 MILLIAMPERES DC SINGLE WINDING |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.005 SECONDS MAXIMUM FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 114.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |