You have reached the quote request page for part number 184-0002 of Autek Systems Corp, we have in stock that is listed alongside the description Relay Electromagnetic. If you would like to learn more about this NSN part and your purchasing options, please fill out and submit the Request the Quote (RFQ) page presented on this page. By offering us important details like your target price and expected fulfillment time frame, our team can best offer you a tailored solution for your consideration. As we have staff available at all times, responses to any submission will be offered within 15 minutes of our review.
Note : We Will Not Share Your Information With Any Third Parties.
To make exploring our expansive inventory simple, we have chosen to list all offerings alongside as much information as we can for an ease of identification. For example, part number 184-0002 is specifically produced under CAGE Code 54817, denoting the specific Autek Systems Corp facility it traces back to. Furthermore, with the NSN 5945-01-116-7041, this item also belongs to FSC 5945 Relays and Solenoids, further ensuring that you only purchase your exact needs. If you have any questions or concerns regarding our offerings or service, be sure to call or email us at your convenience. Otherwise, we look forward to serving you as your strategic sourcing partner for part number 184-0002 and more.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-116-7041 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 011167041 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
M39016-9004 | E | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 0.280 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 390.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CRXH | TIME DELAY | 0.0015 SECONDS MAXIMUM FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.002 SECONDS MAXIMUM FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
FEAT | SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT; LEAD LG 1.500 IN. MINIMUM |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/9 GOVERNMENT SPECIFICATION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote